Sign In Join Help
 
Feyvan Electronics Technology Co., Ltd.

 
 
Recommended Results 
 
Custom XLPE Cable with Drain Wire and Al-Mylar 

  Category : Electronic and electrical->Electronic Parts->Flat Printed Cable

     
Custom XLPE Cable with Drain Wire and Al-Mylar
       

  Product Specification
 
  Model No:      FVC-003
  Country  CN
  Brand  Feyvan
  Packing  Coil, Spool, Carton
  Minimum Order  3050
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p>
<strong><span style="font-size:14px;font-family:Arial;">Feyvan Electronics supplies custom halogen free multicore electrical wire with XLPE &amp; PE insulated and <strong><span style="font-size:14px;font-family:Arial;">XLPE &amp; FRPE&nbsp;</span></strong>jacketed.</span></strong>
</p>
<p>
<strong><span style="font-size:14px;font-family:Arial;"><strong><span style="font-size:14px;font-family:Arial;"><strong><strong>We can satisfy your unique end-use requirements by adding AL-mylar, shielding and cotton and PVC strip fillers&nbsp;<strong><span style="font-size:14px;font-family:Arial;">etc.&nbsp;</span></strong></strong></strong></span></strong><br />
</span></strong>
</p>
<p>
<strong><span style="font-size:14px;font-family:Arial;"><strong><span style="font-size:14px;font-family:Arial;"><strong><strong>Rated temperature range can be changed by using different PE material compounds.</strong></strong></span></strong></span></strong>
</p>
<p>
<strong><span style="font-size:14px;font-family:Arial;"><strong><span style="font-size:14px;font-family:Arial;"><strong><strong><strong><strong><span style="font-size:14px;font-family:Arial;">XLPE insulation material also with&nbsp;excellent heat resistance and mechanical</span></strong><span style="font-size:14px;font-family:Arial;">&nbsp;strength is more steady, low dielectric loss&nbsp;than PVC insulation material</span><span style="font-size:14px;">.</span><span style="font-family:Arial;"><span style="font-size:14px;">&nbsp;It has the&nbsp;properties of&nbsp;excellent electrical performance, aging resistance, chemical corrosion and strong load capacity as well.</span></span></strong><br />
</strong></strong></span></strong></span></strong>
</p>
<p>
<strong><span style="font-size:14px;font-family:Arial;">Applications e.g. general internal wiring of electronic appliance </span><span style="font-size:14px;font-family:Arial;">and electrical&nbsp;</span><span><span style="font-size:14px;font-family:Arial;">equipment lead wire&nbsp;<strong><span style="font-size:14px;font-family:Arial;">of motor, lamp, high-performance appliance and equipment where rated&nbsp;</span></strong><span><span style="font-size:14px;"><b><span style="font-family:Arial;">temperature not exceeding&nbsp;</span><span style="font-family:Arial;">150</span><strong><span style="font-family:Arial;">℃</span></strong><span style="font-family:Arial;">.</span></b></span></span></span></span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;"><br />
</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">Technical Date:</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Rated temperature: </span><span style="font-size:14px;font-family:Arial;">105</span><span style="font-size:14px;"><strong><span style="font-size:14px;font-family:Arial;">℃</span><span style="font-size:14px;font-family:Arial;">,</span></strong><span style="font-family:Arial;"></span><span style="font-family:Arial;">125</span></span><span style="font-size:14px;font-family:Arial;">℃ &amp; 150<strong><span style="font-size:14px;font-family:Arial;">℃ optional</span></strong></span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Rated voltage: 300V &amp; 600V&nbsp;<strong><span style="font-size:14px;font-family:Arial;"><strong>optional</strong></span></strong></span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Reference standard: UL subject 758, UL1581</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Conductor: 30-10AWG&nbsp;<strong>tinned or bare, stranded or solid copper</strong></span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Insulation: XLPE &amp; PE with multiple colors to choose</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Jacket:&nbsp;<strong><span style="font-family:Arial;font-size:14px;">XLPE &amp; FRPE with multiple colors to choose</span></strong>, fillers optional</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Uniform insulation thickness to ensure&nbsp;</span></strong><strong><span style="font-family:Arial;font-size:14px;">easy stripping and cutting</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;">- Passed UL VW-1, cUL FT1 and JQA F-mark flame test</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;"><br />
</span></strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:14px;"><img src="http://i.bosscdn.com/product/e0/09/f3/fee4cc825de030d7a00e26dcf0.jpg" title="Customized XLPE insulation and XLPE jacket cable" alt="Customized XLPE insulation and XLPE jacket cable" /><br />
</span></strong>
</p>
<p>
<br />
</p>
<p>
<strong>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="659" style="border-collapse:collapse;border:none;">
<tbody>
<tr>
<td width="92" rowspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Part Name</span><span style="font-size:10.0pt;font-family:Arial;color:black;"></span>
</p>
</td>
<td width="64" rowspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Conductor</span><span style="font-size:10.0pt;font-family:Arial;color:black;"></span>
</p>
</td>
<td width="99" rowspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Construction</span>
</p>
</td>
<td width="85" rowspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Drain Wire</span>
</p>
</td>
<td width="163" colspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Insulation XLPE</span>
</p>
</td>
<td width="156" colspan="2" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Jacket XLPE</span>
</p>
</td>
</tr>
<tr>
<td width="85" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Thickness</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">mm</span>
</p>
</td>
<td width="78" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Diameter</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">mm</span>
</p>
</td>
<td width="85" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Thickness</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">mm</span>
</p>
</td>
<td width="71" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Diameter</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">mm</span>
</p>
</td>
</tr>
<tr>
<td width="92" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">Custom XLPE</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">3C AWG22</span>
</p>
</td>
<td width="64" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">19/0.16</span>
</p>
</td>
<td width="99" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">3C+Fillers</span>
</p>
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">+Drain Wire+ 100% Al-Mylar</span>
</p>
</td>
<td width="85" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">7/0.32</span>
</p>
</td>
<td width="85" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">0.76</span>
</p>
</td>
<td width="78" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">2.35</span>
</p>
</td>
<td width="85" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">0.76</span>
</p>
</td>
<td width="71" style="border:solid windowtext 1.0pt;background:white;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-size:10.0pt;font-family:Arial;color:black;">7.20</span>
</p>
</td>
</tr>
</tbody>
</table>
<br />
</strong>
</p>
<p>
<strong><span style="font-family:Arial;font-size:16px;">Package options:</span></strong><span style="font-family:Arial;font-size:16px;"></span>
</p>
<p>
<span style="font-family:Arial;font-size:16px;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<img src="http://i.bosscdn.com/product/6f/97/5a/6b5f09cc5d2261b54e8f9e4964.jpeg" title="Package" alt="Package" /></span>
</p>fv-cable-assembly.com

  More Products from this Supplier
 
UL3132 Silicone Rubber Insulated Wire

UL3132 Silicone Rubber Insulated Wire
Bus Audio and Video Cable Assembly

Bus Audio and Video Cable Assembly
Servo Wire Harness for FANUC System Servo Motors

Servo Wire Harness for FANUC System Servo Motors
UL3266 Cross linked Polyethylene Electrical Wire

UL3266 Cross linked Polyethylene Electrical Wire
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .